Full data export and cross-reference analysis: - 7,550 GenieACS devices with IPs, deviceId, tags - 6,720 legacy devices (raisecom, tplink, onu categories) - 16,056 fibre table entries (OLT frame/slot/port/ontid, VLANs) - 8,434 legacy services linked to devices Key finding: CWMP serial ≠ physical serial. Only 22/7,550 devices are tagged with their physical serial (RCMG/TPLG). Raisecom MAC is extractable from CWMP serial suffix. TP-Link CWMP serial = sticker serial for ONT models. Matching strategy documented: tag-based, MAC-based, OLT port-based. Recommends bulk tagging via OLT query as first step. Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
5.3 KiB
5.3 KiB
GenieACS ↔ Legacy System ↔ ERPNext — Device Matching Analysis
Data Sources
| Source | Records | Key Fields |
|---|---|---|
| GenieACS (NBI) | 7,550 devices | CWMP serial, OUI, ProductClass, IP, tags, _lastInform |
Legacy device table |
10,417 devices | delivery_id, category, sn (physical), mac, manage IP, parent |
Legacy fibre table |
16,056 entries | sn (physical), OLT frame/slot/port/ontid, olt_ip, VLANs |
Legacy service table |
66,686 services | delivery_id, device_id, product_id, radius_user/pwd |
Legacy delivery table |
17,131 deliveries | account_id, address, city, zip |
| ERPNext Service Equipment | ~10,000 | serial_number, mac_address, customer, service_location |
GenieACS MariaDB wifi |
unknown | serial, instance, ssid, password |
GenieACS MariaDB voip |
unknown | serial, instance, username, password |
Fleet Breakdown
GenieACS (by model)
- Device2 (TP-Link Deco XE75/XX230v): 4,051 (74% online)
- HT803G-W (Raisecom GPON ONT): 493
- HT803G-WS2 (Raisecom GPON ONT v2): 2,340
- Device 2 (older TP-Link): 409
- DISCOVERYSERVICE: 156 (ghost entries)
- HT502/HT812 (Grandstream ATA): ~70
- GXP2130/2160/1630 (Grandstream phones): ~20
- XX530v/XGB430v_Pro (TP-Link VoIP): 4
Legacy (by category)
- raisecom_rcmg: 5,016
- stb_ministra: 1,212
- stb: 1,054
- tplink_tplg: 849
- tplink_device2: 811
- airosm: 832 (Ubiquiti AirOS)
- airos_ac: 228
- cambium: 118
- onu: 40
- ht803g1ge: 4
Matching Strategy
Key Discovery: CWMP Serial ≠ Physical Serial
GenieACS stores the CWMP negotiated serial number, which is an internal identifier — NOT the physical label serial.
Raisecom HT803G-W pattern:
CWMP Serial: 7IGLC980074DF9D98
^^^^^^^^^^^^
= MAC address (98:00:74:DF:9D:98)
Tag (physical SN): RCMG19E0AB57
TP-Link Device2 pattern:
CWMP Serial: 2234196001225 (manufacturing serial, same as sticker)
Tag: config_manuelle (NOT the serial)
Raisecom Matching: CWMP Serial → MAC → OLT → Fibre → Customer
- Extract MAC from CWMP serial: Last 12 hex chars = MAC (e.g.,
980074DF9D98→98:00:74:DF:9D:98) - But legacy
device.macfield is mostly empty (only 28/5,016 have it) - Alternative: The 22 tagged devices have
RCMG...physical serial in tags - Best path: OLT registration maps GPON SN → frame/slot/port → fibre table
Proposed workflow:
- Query each OLT for registered ONT serial numbers and their port assignments
- Match OLT data →
fibre.frame/slot/port/ontid→fibre.service_id→service.delivery_id→delivery.account_id - Tag each GenieACS device with its RCMG physical serial from OLT data
TP-Link Matching: CWMP Serial = Sticker Serial
For TP-Link devices, the CWMP serial IS the sticker serial (e.g., TPLGA1E7FB90).
But most TP-Link Device2 (Deco) have alphanumeric serials like 2234196001225.
Match via MAC address:
- GenieACS has
Device.Ethernet.Interface.1.MACAddressfor Device2 - Legacy has
device.macfortplink_device2category - ERPNext Service Equipment has
mac_address
Recommended Matching Script
# Priority order for matching:
# 1. Tag (physical serial) → fibre.sn or device.sn (exact match, highest confidence)
# 2. MAC address → device.mac or ERPNext mac_address (when available)
# 3. CWMP serial last 12 chars as MAC → MAC-based lookup
# 4. WAN IP (172.17.x.x) → device.manage or fibre OLT topology
# 5. Manual matching for remainder (present device list for human review)
Actions Required
Immediate: Bulk Tag GenieACS Devices
The biggest gap is that only 22/7,550 devices have their physical serial as a tag. Two approaches:
A. Script via OLT (recommended):
- SSH to each OLT (the
info_connectIPs: 172.17.0.x) - Run
display ont infoor equivalent to get GPON SN → port mapping - Cross-reference with
fibretable (frame/slot/port/ontid) - Push tags to GenieACS via NBI:
POST /devices/:id/tags/:serial
B. Enrichment via CWMP serial MAC extraction:
- For Raisecom: extract last 12 chars of CWMP serial as MAC
- Match to any MAC-indexed data source
- Tag via NBI
Medium-term: Migrate WiFi/VoIP Provisioning Data
The GenieACS MariaDB at 10.5.14.21 is not accessible from all servers.
Export the wifi and voip tables and migrate to:
- ERPNext custom fields on Service Equipment (preferred)
- Or a new provisioning table in the targo-hub database
For Oktopus: Device Profiles
Map each device category to an Oktopus device profile:
| Legacy Category | GenieACS Model | Oktopus Profile | Config |
|---|---|---|---|
| raisecom_rcmg | HT803G-W/WS2 | raisecom-ont | VoIP DSCP, NTP, UPnP off, bridge mode |
| tplink_tplg | Device2 (GPON) | tplink-ont | WiFi SSID/pwd from DB |
| tplink_device2 | Device2 (Deco) | tplink-deco | WiFi SSID/pwd, mesh config |
| onu | Various | generic-ont | Basic monitoring |
| ht803g1ge | HT803G-1GE | raisecom-1ge | Legacy single-port ONT |
Data Volumes Summary
| Match Type | Count | Confidence |
|---|---|---|
| GenieACS tagged with physical SN | 22 | 100% |
| TP-Link CWMP serial = sticker serial | ~5,000 | High |
| Raisecom MAC extractable from CWMP SN | ~2,833 | Medium |
| Legacy fibre with SN | 4,948 | Reference |
| Legacy device with SN | ~5,900 | Reference |
| Needs OLT query for matching | ~2,800 Raisecom | Required |